CPR-1621-1M21 Specification
Page 4 of 37
AC Line Surge Transient Performance
Duration Surge Operating AC Voltage Line Frequency Performance Criteria Continuous
10% Nominal AC Voltages 50/60 Hz No loss of function or performance
0 to 1AC cycle
30% Mid-point of nominal AC Voltages 50/60 Hz No loss of function or performance
2.8 AC Line Fast Transient Specification
The power supply shall meet the EN61000-4-5 directive and any additional requirements in IEC1000-45:1995 and the Level 3 requirements for surge-withstand capability, with the following conditions and exceptions:
â¢
These input transients must not cause any out-of-regulation conditions, such as overshoot and undershoot, nor must it cause any nuisance trips of any of the power supply protection circuits.
â¢
The surge-withstand test must not produce damage to the power supply.
â¢
The supply must meet surge-withstand test conditions under maximum and minimum output load conditions.
3 DC Output Specification
3.1 Output regulation Requirements
All outputs must maintain their regulation with the below limits when measured at the output connector point or across the remote sense (if applicable) in any load condition defined in section 3.2
Voltage Regulation Limit
s Output Minimum Nominal Maximum Unit +12V
11.40 12.0 12.60
Vdc +5Vsb
4.75 5.0 5.25
Vdc
There should never be any negative voltage for all outputs and signals during all occasion, including power on and off. During standby (PSON=off), all outputs, except +5VSB, should be below 50mV.
3.2 Output Current Requirements
All outputs must maintain their regulation as section 3.1 when loaded to the following loading