( Krypton Interrupter zener heatsink - zener slots ( Set start reference datum at x-1000, y5000 ( Install 9 mm ball nosed drill ( Spindle speed set to 2000~2500rpm ( operation begins automatically when quil TDC switch is opened ( raise the quill at the end of the last X+zzzmm stroke ( with appropriate care the part can be remove the part during the parked condition ( 80% Kero+ 20% RTD used as cutting lubricant during the X+13100mm cutting stroke ( return speed may be increased if justified by higher production rate clr ( clear all existing programs/commands p ( begin programme m 1 ( set motor to FULL step mode t 200 ( set start speed to 200 steps/sec max 400 ( set MAXimum motor speed to steps per sec. i.e. 400 steps/sec a 500 ( set acceleration to 500 steps/sec/sec de 500 ( set deceleration to 1500 steps/sec/sec k 50 ( sets step constant to 50 ? s 4 0 ( drill up x 550 ( move "x" axis +5.50mm y 400 ( move "y" axis 4.00mm s 4 1 ( lower tool o 1 1 w 40 ( delay 6 seconds for drill penetration max 100 ( set MAXimum motor speed to steps per sec y 4200 ( cut slot 1 o 1 0 s 4 0 ( raise tool max 400 x 1000 ( move across 10 mm max 100 s 4 1 ( lower tool o 1 1 w 40 ( delay 5 seconds for drill penetration y -4200 ( cut slot 2 o 1 0 s 4 0 ( raise tool max 400 x 1000 ( move across 10 mm max 100 s 4 1 ( lower tool o 1 1 w 40 ( delay 5 seconds for drill penetration y 4200 ( cut slot 3 o 1 0 s 4 0 ( raise tool max 400 x 1000 ( move across 10 mm max 200 s 4 1 ( lower tool o 1 1 w 40 ( delay 5 seconds for drill penetration y -4200 ( cut slot 4 o 1 0 s 4 0 ( raise tool max 400 x 1000 ( move across 10 mm max 100 s 4 1 ( lower tool o 1 1 w 40 ( delay 5 seconds for drill penetration y 4200 ( cut slot 5 o 1 0 s 4 0 ( raise tool max 400 x 1000 ( move across 10 mm max 100 s 4 1 ( lower tool o 1 1 w 40 ( delay 5 seconds for drill penetration y -4200 ( cut slot 6 o 1 0 s 4 0 ( raise tool max 400 x 1000 ( move across 10 mm max 100 s 4 1 ( lower tool o 1 1 w 40 ( delay 5 seconds for drill penetration y 4200 ( cut slot 7 o 1 0 s 4 0 ( raise tool max 400 x 1000 ( move across 10 mm max 100 s 4 1 ( lower tool o 1 1 w 40 ( delay 5 seconds for drill penetration y -4200 ( cut slot 8 o 1 0 s 4 0 ( raise tool max 400 ( set MAXimum motor speed to steps per sec. i.e. 400 steps/sec x -7550 ( return home y -400 s 4 0 ( BDC switch OPEN - press is cycling or at TDC s 4 1 ( BDC switch CLOSED - identifies that drill is in the part c 0 ( turn motor current off g ( go to begining and repeat as often as job/parts require