IBM System x3650 Baseboard Management Controller (BMC) Windows Update
Version 1.49 (Build ID GGBT61AUS)

System Machine Type 7979, 1914.

CONTENTS
________

1.0  Overview
2.0  Installation and Setup Instructions
3.0  Configuration Information
4.0  Unattended Mode
5.0  Web Sites and support phone Number
6.0  Trademarks and Notices
7.0  Disclaimer


1.0  Overview
________________________

        1.1     This package will update the Baseboard Management
                Controller (BMC) firmware only.  It will not affect
                any device drivers.

        1.2     Limitations

                If there is an error in loading the BMC firmware
                retry loading the software by repeating the
                instructions in section 2.

        1.3     Enhancements

                - IPMI

        1.4.    Level of Recommendations and Prerequisites for the
                update:

                - BIOS version 1.00, or later, must be installed prior to
                  installing this ISMP firmware update.

                - A full tape backup should be completed and verified
                  prior to running this, or any other system upgrade.

                - RAID configuration should be saved to a diskette:
                  see the "Hardware Maintenance Manual" for more details.

                - An IPMI driver is required to perform this update.  The
                  OSA device driver must be installed with the accompanying
                  IBM IPMI mapping layer.

        1.5     Dependencies:

                - none

2.0  Installing and Setup Instructions
______________________________________

        2.1   Step by step instructions for this code update (GUI)

              - Run the "IBM System x3650 Windows BMC Update"
                by double-clicking the .EXE.

              - Choose "Perform Update" and click the "Next" button.

              - If the update is meant for the system on which it is
                running, the "Next" button will appear.  Click the "Next"
                button to continue.

              - Click the "Exit" button.

        2.2   Step by step instructions for extracting the Windows update
              files (GUI)

              - Run the "IBM System x3650 Windows BMC Update"
                by double-clicking the .EXE.

              - Choose "Extract to Hard Drive" and click the "Next"
                button.

              - Choose a directory into which the Windows update files
                will be saved in the "Save As" dialog.

              - The files extracted are all the files that are necessary to
                perform a BMC update under Windows.  Run "wflash -c" from a
                command line to update BMC on 32-bit Windows or "wflash64 -c"
                from a command line to update BMC on 64-bit Windows.

              - Click the "Exit" button.

        2.3   Step by step instructions for extracting the DOS update
              files to diskette (GUI)

              - Run the "IBM System x3650 Windows BMC Update"
                by double-clicking the .EXE.

              - Choose "Extract to Floppy" and click the "Next"
                button.

              - Place a diskette in the A: drive and press the "OK" button.

              - The diskette created is the DOS BMC update diskette.

              - Click the "Exit" button.

        2.4   Step by step instructions for extracting the DOS update
              files to diskette (command line)

              - Run the "IBM System x3650 Windows BMC Update"
                with the following command line:

                   "<update>.exe -a -xd <drive>" where <update>.exe is the
                   downloaded update and <drive> is the drive to which the
                   DOS update files will be extracted.


3.0  Configuration Information
______________________________________

        There is no configuration information necessary.


4.0     Unattended Mode
_______________________

        4.1   Performing the update in unattended mode

              - Run the "IBM System x3650 Windows BMC Update"
                with the following command line:
                
                   "<update>.exe -s -a -s" where <update>.exe is the
                   downloaded update.

        4.2   Performing the update in ultrasilent mode

              - Run the "IBM System x3650 Windows BMC Update"
                with the following command line:
                
                   "<update>.exe -s -a silent" where <update>.exe is the
                   downloaded update.

              Any output to the screen will be suppressed and no exit code
              is returned, since the installer application returns immediately
              and the update actually runs in the background.

              NOTE: If it is necessary to verify the return code from the
              actual update once this is finished, check the latest entry
              added to file <drive>:\UXLOG\UX.LOG, where <drive> is the
              Windows System Drive value.

        4.3   Performing the update in ultrasilent mode with output directed
              to file <drive>:\flshlog\flshout.log where <drive> is the
              Windows System Drive value

              - Run the "IBM System x3650 Windows BMC Update"
                with the following command line:
                
                   "<update>.exe -s -a dumptofile" where <update>.exe is the
                   downloaded update.

              Any output to the screen will be suppressed and no exit code
              is returned, since the installer application returns immediately
              and the update actually runs in the background.

              NOTE: If it is necessary to verify the return code from the
              actual update once this is finished, check the latest entry
              added to file <drive>:\UXLOG\UX.LOG, where <drive> is the
              Windows System Drive value.

        4.4   Extracting the Windows update files in unattended mode
        
              - Run the "IBM System x3650 Windows BMC Update"
                with the following command line:
                
                   "<update>.exe -s -a -x <path>" where <update>.exe is the
                   downloaded update and <path> is the path to which the
                   Windows update files will be extracted.

        4.5   Running extracted Windows update files in unattended mode

              - Extract the Windows update files using Section 2.2
                or Section 4.4 of this readme.

              - Run "wflash -c" from a command line to update BMC on 32-bit
                Windows or run "wflash64 -c" from a command line to update
                BMC on 64-bit Windows.

        4.6   Running extracted Windows update files in ultrasilent mode

              - Extract the Windows update files using Section 2.2
                or Section 4.4 of this readme.

              - Run "wflash -c silent" from a command line to update BMC on
                32-bit Windows or run "wflash64 -c silent" from a command line
                to update BMC on 64-bit Windows. Any output to the screen will
                be suppressed and only an exit code is returned.

        4.7   Running extracted Windows update files in ultrasilent mode with
              output directed to file <drive>:\flshlog\flshout.log, where
              <drive> is the Windows System Drive value

              - Extract the Windows update files using Section 2.2
                or Section 4.4 of this readme.

              - Run "wflash -c dumptofile" from a command line to update BMC on
                32-bit Windows or run "wflash64 -c dumptofile" from a command
                line to update BMC on 64-bit Windows. Any output to the screen
                will be suppressed and only an exit code is returned.

5.0     WEB Sites and Support Phone Number
__________________________________________

        5.1     IBM Support Web Site:
                http://www.pc.ibm.com/support

        5.2     IBM System x Web Site:
                http://www.ibm.com/systems/x/


6.0.    TradeMarks and Notices
______________________________

        6.1     The following terms are trademarks of the IBM
                Corporation in the United States, or other countries
                or both:
                            * IBM
                            * Netfinity
                            * Netfinity Manager
                            * Advanced System Management

                Other company, product, and service names may be
                trademarks or service marks of others.


7.0.    Disclaimer
__________________

        7.1     THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF
                ANY KIND.  IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS
                OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED
                WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND
                MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN
                THIS DOCUMENT.  BY FURNISHING THIS DOCUMENT, IBM
                GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS.

        7.2     Note to Government users:

                Note to U.S. Government users-- Documentation related
                to restricted rights-- Use, duplication and disclosure
                is subject to restrictions set forth in GSA ADP Schedule
                Contract with IBM Corporation.


(C) Copyright International Business Machines Corporation 2008.